台湾WILSHEN伟圣单向减压阀
RCG系列单向减压阀部分型号:
RCG-03-1-31 RCT-03-1-31
RCG-06-1-31 RCT-06-1-31
RCG-10-1-31 RCT-10-1-31
RCG-03-2-31 RCT-03-2-31
RCG-06-2-31 RCT-06-2-31
RCG-10-2-31 RCT-10-2-31
RCG-03-3-31 RCT-03-3-31
RCG-06-3-31 RCT-06-3-31
RCG-10-3-31 RCT-10-3-31
RCG-03-1-30 RCT-03-1-30
RCG-06-1-30 RCT-06-1-30
RCG-10-1-30 RCT-10-1-30
RCG-03-2-30 RCT-03-2-30
RCG-06-2-30 RCT-06-2-30
RCG-10-2-30 RCT-10-2-30
RCG-03-3-30 RCT-03-3-30
RCG-06-3-30 RCT-06-3-30
RCG-10-3-30 RCT-10-3-30 1322
台湾WILSHEN伟圣减压阀
RG系列减压阀部分型号:
RG-03-1-31 RT-03-1-31
RG-06-1-31 RT-06-1-31
RG-10-1-31 RT-10-1-31
RG-03-2-31 RT-03-2-31
RG-06-2-31 RT-06-2-31
RG-10-2-31 RT-10-2-31
RG-03-3-31 RT-03-3-31
RG-06-3-31 RT-06-3-31
RG-10-3-31 RT-10-3-31
RG-03-1-30 RT-03-1-30
RG-06-1-30 RT-06-1-30
RG-10-1-30 RT-10-1-30
RG-03-2-30 RT-03-2-30
RG-06-2-30 RT-06-2-30
RG-10-2-30 RT-10-2-30
RG-03-3-30 RT-03-3-30
RG-06-3-30 RT-06-3-30
RG-10-3-30 RT-10-3-30
台湾WILSHEN伟圣压力控制阀
HC型压力控制阀部分型号:
HCG-03-A-1 HCG-06-A-1 HCG-10-A-1
HCT-03-A-1 HCT-06-A-1 HCT-10-A-1
HCG-03-A-2 HCG-06-A-2 HCG-10-A-2
HCT-03-A-2 HCT-06-A-2 HCT-10-A-2
HCG-03-A-3 HCG-06-A-3 HCG-10-A-3
HCT-03-A-3 HCT-06-A-3 HCT-10-A-3
HCG-03-A-4 HCG-06-A-4 HCG-10-A-4
HCT-03-A-4 HCT-06-A-4 HCT-10-A-4
H型压力控制阀部分型号:
HG-03-A-4 HT-03-A-4
HG-06-A-4 HT-06-A-4
HG-10-A-4 HT-10-A-4
HG-03-A-1 HT-03-A-1
HG-06-A-1 HT-06-A-1
HG-10-A-1 HT-10-A-1
先导阀弹簧(调压弹簧)错装成软弹簧,或者因弹簧疲劳产生变形或者折断等原因,造成p2压力调不高,只能调到某一低的定值,此值远低于减压阀的调节压力。
调压手柄因螺纹拉伤或有效深度不够,不能拧到底而使得压力不能调大。
阀盖与阀体之间的密封不良,严重漏油。产生原因可能是O形圈漏装或损伤,压紧螺钉未拧紧以及阀盖加工时出现端面平面度误差,一般是四周凸,中间凹。
主阀芯因污物、毛刺等卡死在小开度的位置上,使出口压力低。可进行清洗与去毛刺。